Application
Inspection of welds,
including thin-walled objects. Control tubes, pressure vessels,
containers, pumps and valves, turbine
blades, shafts, wheels.
Features and Benefits:
-
rugged, ergonomic
case converter;
-
the size and
frequency of the piezoelectric element correspond to the
nomenclature of GE;
-
the maximum
frequency of the characteristics of transducers provide a
simple calibration;
-
possible
replacement of the foot (sold separately);
-
sockets for 00
series standard converters;
-
long life.
Main
technical characteristics
-
Rectangular
piezoplates 8x9 mm.
-
The thickness of the
sole of 2 mm.
-
Dimensions 25x17x20
mm.
-
Size of the working
surface 22x14 mm.
|
Designation |
Angle, ° |
Frequency, MHz |
Similar
to GE |
|
PA 2-45 |
45 |
2 |
MWB45-2 |
|
PA 2-60 |
60 |
MWB60-2 |
|
PA 2-70 |
70 |
MWB70-2 |
|
PA 4-45 |
45 |
4 |
MWB45-4 |
|
PA 4-60 |
60 |
MWB60-4 |
|
PA 4-70 |
70 |
MWB70-4 |
|
Direct
ultrasonic transducers for general purposes
|
Application

Control of metal
products simple geometric forms of manual control panels, large
forgings, castings. Converters small contact area for the
control of pipes and tanks, control exfoliation.
Converters with a
large contact area is used for the control of products with high
attenuation of ultrasound or thick-walled products.
Features and Benefits:
-
abrasion resistant
protector of the working surface;
-
the size and frequency
of the piezoelectric element correspond to the nomenclature of
GE;
-
rugged ergonomic case
sockets for 00 series standard converters.
|
Designation |
Operating
range, mm |
Element size,
mm |
Frequency, MHz |
Similar
to GE |
|
P111-1G |
15-2300 |
24 |
1 |
K1G |
|
P111-4G |
10-4000 |
24 |
2 |
K2G |
|
P111-2G |
7-8000 |
24 |
4 |
K4G |
|
P111-1N |
15-420 |
10 |
1 |
K1G |
|
P111-2N |
7-2500 |
10 |
2 |
K2G |
|
P111-4N |
5-5000 |
10 |
4 |
K4G |
|
P111-5N |
4-6300 |
10 |
5 |
K5G |
|
P111-6N |
3-7600 |
10 |
6 |
K6G |
|
Ultrasonic
transducers for thickness gauges GE
|
Application

Measurement of
residual thickness of metal products. Identify pockets of
corrosion of pipes.
Features and Benefits:
-
rugged, ergonomic
case converter;
-
the size and
frequency of the piezoelectric element correspond to the
nomenclature of GE;
-
compatible with
standard cables;
-
maximum frequency
characteristics of the transducers provides a simple
calibration of thickness gauge;
-
sockets for 00
series standard converters;
-
wear indicator
transducers on the body.
|
Designation |
Operating
range, mm |
Element size,
mm |
Frequency, MHz |
Similar
to GE |
|
P112-DA301 |
1,2-200 |
11/2 |
5 |
DA301 |
|
P112-DA312 |
0,6-25 |
6/2 |
10 |
DA312 |
|
Ultrasound Dual
element transducers for flaw GE
|
Application

Detection of
subsurface defects and to measure the thickness of thin sheets.
Control of objects
with high attenuation of ultrasound and heavily corroded
surface.
Control of bolts,
studs.
Converters with a
small contact area suitable for the testing of pipes and
vessels.
Control of railway
wheels.
Features and advantages:
-
excellent
resolution at the surface of the controlled products;
-
low impact radius
and roughness of the controlled product tj identify defects;
-
the size and
frequency of the piezoelectric element correspond tj the
nomenclature of GE;
-
sockets for
00series standard converters.
|
Designation |
Operating
range, mm |
Element size,
mm |
Frequency, MHz |
Similar
to GE |
|
P112-SEB2 |
2-1000 |
7x18 |
2 |
SEB2 |
|
P112-SEB4 |
1,5-2000 |
6x20 |
4 |
SEB4 |
|
P112-MSEB2 |
2-400 |
Ф11 |
2 |
MSEB2 |
|
P112-MSEB4 |
1-1500 |
3,5x10 |
4 |
MSEB4 |
|
Ultrasonic
transducers for thickness gauges Panametrics
|
Application
Measurement of
residual thickness of metal products. Identify pockets of
corrosion of pipes when working with a thickness gauge 26MG,
MG2, MG2XT, MG2DL, 37DL.
Features and
Benefits:
-
run in prism, and
the frequency of the piezoelectric element correspond to the
nomenclature of Panametrics;
-
built-in cable for
00 series standard converters;
-
maximum frequency
characteristics of the transducers provides a simple
calibration of thickness gauges;
-
can be used with a
thickness gauge of other manufacturers;
-
wear indicator
transducers on the body.
|
Designation |
Operating
range, mm |
Element size,
mm |
Frequency, MHz |
Similar
to Panametrics |
|
P112-D706 |
2-200 |
18 |
2,25 |
D706 |
|
P112-D709 |
1-1500 |
18 |
5 |
D709 |
|
P112-D792 |
0,6-25 |
8 |
10 |
D792 |
|
P112-D799 |
1-75 |
12 |
5 |
D799 |
|
Probes for
thickness gauge B5
|
Application
Measurement of
residual thickness of metal products. Identify pockets of
corrosion of pipes.
Features and Benefits:
-
built-in memory
for instant adjustment thickness gauge;
-
high sensitivity
and wide measurement range toschin;
-
low impact of
temperature change in the control product;
-
long service life;
-
small effect of
the curvature and roughness of the controlled object;
-
built-in
connectors for 00 series converters large;
-
for probes 5T12
possibility of measuring up to 250°C.
|
Designation |
Operating
range, mm |
Overall
dimensions, mm |
Frequency, MHz |
Element
size, mm |
|
5A10 |
1-200 |
Ф9x11 |
5 |
10 |
|
10A6 |
0,6-20 |
Ф18x26 |
10 |
6 |
|
5T12 |
1,50300 |
Ф27x50 |
5 |
14 |
|
10A4 |
0,5-10 |
Ф9x11 |
10 |
Ф4,5 |
|
2,5A10 |
1,5-100 |
Ф9x11 |
2,5 |
10 |
|
Test block of
ISO 7963.BS2704 V 2
|
-
Settings duration
sweep when working with direct and oblique transducers.
-
Determine the
point of "0" output of ultrasonic vibrations and arrows
oblique converter.
-
Definitions of the
input angle oblique transducers.
-
Sensitivity flaw
with direct and oblique transducers.
|
Test block of
ISO 2400:1972 V1
|
-
To adjust the
depth and flaw check the linearity of the scan.
-
Customize the
depth flaw for transverse waves.
-
Setting up a sweep
rate for transverse waves.
-
Definitions of the
exit point of ultrasound transducer and arrows oblique.
-
Definitions of the
input angle oblique transducer.
-
Check the minimum
depth, "dead: zone, direct or separate-combined transducers.
-
Check the
resolution of direct converters.
-
Jobs conventional
flaw detector sensitivity using direct and oblique
transducers.
-
Sample-step is for
the alignment of ultrasonic thickness gauges.
-
Material samples